Why Lowering Air Pressure from 7 Bar to 4 Bar Pays Off

In many plants the compressor is set for the most demanding single consumer, so the whole system runs at a higher pressure than needed. This article explains the gain from lowering pressure and a safe way to do it.

Published: 25 October 2026 · 6 min read

In short

The higher the compressor pressure, the more electricity it uses: about 6–8% per bar. Finding the lowest pressure that every point needs and setting the system to it cuts both energy and leak flow. The target is not “4 bar” as a number, but “enough pressure everywhere”.

Relative compressor energy use≈ 7% / bar (approximate)%1007 bar%936 bar%865 bar%794 bar

Why does system pressure matter so much?

The higher the pressure a compressor squeezes air to, the more electricity it uses. In practice each extra bar raises compressor energy by about 6–8%. Going from 7 bar to 4 bar therefore means a theoretical energy saving of around 20%.

There is a second benefit: air escaping through leaks also drops. For the same hole, leak flow at 4 bar is about 37% lower than at 7 bar. Lower pressure reduces both the cost of each unit of air and the amount of air wasted.

Is 4 bar really possible?

Not in every plant. Pressure must be sufficient at the consumer inlet, not at the compressor outlet. Because filter, dryer, piping and fitting pressure drops add on top, most plants set the compressor at 6–7 bar. The right sequence is:

What is the long-term gain?

Example: a compressor drawing an average of 55 kW and running 6,000 hours a year uses 330,000 kWh. A pressure reduction worth about 20% means 66,000 kWh saved; multiply by your electricity price to get the yearly amount.

What to watch for

Before lowering pressure, list the critical points that could stop production. Check:

Frequently asked questions

Is the saving really 7% per bar?

It is an approximation; it ranges between 6% and 8% depending on compressor type and control method. Determine the real gain from kWh measured before and after the change.

What if 4 bar is not enough?

First find which consumer needs the higher pressure. Often a separate line, a larger cylinder or a local booster for that single application is more economical than keeping the whole system at high pressure.

Does lowering pressure remove leaks?

No, it only reduces leak flow. Finding and repairing leaks is a separate job and usually gives the fastest payback.

Figures given are typical values; the real saving in your plant is determined by measurement.